Reduced fluoroscopy time with physician-controlled fluoroscopy during endoscopic retrograde cholangiopancreatography: A community hospital experience

Affiliations

Russell Research Institute, Advocate Lutheran General Hospital

Abstract

Background and objective: Fluoroscopy during endoscopic retrograde cholangiopancreatography (ERCP) is associated with radiation exposure and related health risks. Either the physician or the radiology technologist can activate fluoroscopy during ERCP. The aim of this study was to determine if physician-controlled fluoroscopy is associated with decreased fluoroscopy time, which may correspond to less radiation exposure to patients and staff.

Methods: We conducted a single-center, retrospective study; data were collected on ERCP performed using physician-controlled and technologist-controlled fluoroscopy. Fluoroscopy time, procedure complexity level, and Stanford Fluoroscopy Score were compared between the two groups.

Results: The median fluoroscopy time significantly differed between the two groups with 108 seconds for physician-controlled and 146 seconds for technologist-controlled procedures (p=0.004). The ratio of median fluoroscopy time to procedure complexity level was significantly lower in the physician-controlled group at 73.0 seconds compared to 97.0 seconds in the technologist-controlled group (p=0.002). The ratio of median fluoroscopy time to Stanford Fluoroscopy Score was 25.5 seconds in the physician-controlled group compared to 39.3 seconds in the technologist-controlled group, which was also statistically significant (p<0.001). A subgroup analysis of physicians with advanced training in ERCP also showed a significantly reduced median fluoroscopy time to Stanford Fluoroscopy Complexity Score ratio: 25.5 seconds for physician-controlled versus 35.0 seconds for technologist-controlled (p=0.001).

Conclusion: The ERCP technique with physician-controlled fluoroscopy may be associated with shorter fluoroscopy time. This may correspond to decreased radiation exposure to patients compared to radiology technologist-controlled fluoroscopy. Further investigations with larger, prospective studies are warranted.

Document Type

Article

PubMed ID

33842147

Link to Full Text

 

Share