Background: Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices. However, there are limited data regarding adherence to recommendations among paediatric electrophysiologists, and there are no data regarding cardiac implantable electronic device-related ancillary testing.

Methods: To assess current clinical practices for cardiac implantable electronic device in-person evaluation, remote monitoring, and cardiac implantable electronic device-related ancillary testing, the Paediatric and Congenital Electrophysiology Society members were surveyed. The main outcome measures were variations in frequency of in person evaluation, frequency of remote monitoring, and cardiac implantable electronic device-related ancillary testing.

Results: All respondents performed in-person evaluation at least once a year, but50% ventricular pacing. Majority of respondents (75%) did not perform either an exercise stress test or ambulatory Holter monitoring or chest X-ray (65%) after cardiac implantable electronic device implantation.

Conclusion: This survey identified significant practice variations in cardiac implantable electronic device in- person evaluation, remote monitoring, and ancillary testing practices among paediatric electrophysiologists. Cardiac implantable electronic device management may be optimised by development of a paediatric-specific guidelines for follow-up and ancillary testing.