Association of remote dielectric sensing and six-minute walk distance among those with severe aortic stenosis
Recommended Citation
Imamura T, Narang N, Izumida T, et al. Association of remote dielectric sensing and six-minute walk distance among those with severe aortic stenosis. J Cardiol. 2023;82(4):257-260. doi:10.1016/j.jjcc.2023.05.004
Abstract
Background: Remote dielectric sensing (ReDS) is a novel non-invasive electromagnetic energy-incorporated technology to quantify lung fluid levels. The six-minute walk test is an established method to assess exercise capacity among those with a variety of chronic conditions related to heart and pulmonary diseases. We aimed to understand the association between ReDS value and six-minute walk distance (6MWD) in patients with severe aortic stenosis being evaluated for valve replacement.
Methods: Patients who were hospitalized to receive trans-catheter aortic valve replacement were prospectively included and simultaneous ReDS and 6MWD measurements were performed on admission. We attempted to correlate 6MWD with ReDS value.
Results: A total of 25 patients (median 85 years, 11 men) were included. Median 6MWD was 168 (133, 244) meters and median ReDS value was 26 % (23 %, 30 %). 6MWD displayed a moderate inverse correlation with ReDS value (r = -0.516, p = 0.008) and significantly distinguished ReDS value ≥30 %, representing mild or greater pulmonary congestion, at a cut-off of 170 m (sensitivity 0.67 and specificity 1.00).
Conclusions: 6MWD had a moderate inverse correlation with ReDS values among candidates for trans-catheter aortic valve replacement, indicating that patients with shorter 6MWD had increased pulmonary congestion as assessed by ReDS system.
Document Type
Article
PubMed ID
37209905
Affiliations
Advocate Christ Medical Center