Suture closure AFtEr large bore vein access (SAFE-VEIN): A randomized, prospective study of the efficacy and safety of venous closure device

Affiliations

Aurora Sinai/Aurora St. Luke's Medical Centers

Abstract

Background: Perclose ProGlide (PPG) Suture-Mediated Closure System™ is safe and can reduce time to hemostasis following procedures requiring arterial access.

Aims: We aimed to compare PPG to figure of 8 suture in patients who underwent interventional catheter procedures requiring large bore venous access (LBVA) (≥13 French).

Methods: In this physician-initiated, randomized, single-center study [clinicaltrials.gov ID: NCT04632641 ], single-stick venous access was obtained under ultrasound guidance. Eligible patients were randomized 1:1, and 100 subjects received allocated treatment to either PPG (n = 47) or figure of 8 suture (n = 53). No femoral arterial access was used in any patient. Primary outcomes were time to achieve hemostasis (TTH) and time to ambulation (TTA). Secondary outcomes were time to discharge (TTD) and vascular-related complications and mortality. Wilcoxon rank-sum test was used to compare TTH, TTA, and TTD.

Results: TTH (minutes) was significantly lower in PPG versus figure of 8 suture [median, (Q1, Q3)] [7 (2,10) vs. 11 (10,15) respectively, p < 0.001]. TTA (minutes) was significantly lower in PPG compared to figure of 8 suture [322 (246,452) vs. 403 (353, 633) respectively, p = 0.005]. TTD (minutes) was not significantly different between the PPG and figure of 8 suture arms [1257 (1081, 1544) vs. 1338 (1171,1435), p = 0.650]. There was no difference in minor bleeding or access site hematomas between both arms. No other vascular complications or mortality were reported.

Conclusion: PPG use had lower TTH and TTA than figure of 8 suture in a population of patients receiving LBVA procedures. This may encourage same-day discharge in these patients.

Type

Article

PubMed ID

39087741


 

Share

COinS