"Leaking hepatic artery aneurysm successfully treated with covered sten" by Abdelazim Hashim, Suhail Allaqaband et al.
 

Leaking hepatic artery aneurysm successfully treated with covered stent

Affiliations

Aurora Sinai/Aurora St. Luke’s Medical Centers

Abstract

Hepatic artery aneurysm (HAA) is rare with reported incidence of 0.02%. It accounts for approximately 12-20% of all visceral aneurysms. The reported risk of rupture ranges from 14% to 80% of all HAAs. Traditionally, HAA has been treated surgically or by transcatheter coil embolization. There are few published reports of percutaneous HAA stenting. We report a case of a 72-year-old female with leaking HAA who was successfully treated with endovascular stenting. The authors include a review of the relevant literature.

Document Type

Article

PubMed ID

19522005

Link to Full Text

 

Plum Print visual indicator of research metrics
PlumX Metrics
  • Citations
    • Citation Indexes: 14
  • Usage
    • Abstract Views: 6
  • Captures
    • Readers: 7
see details

Share

COinS